Water-Year Summary for Site 01467087

Click to hide Water-Year Summary instructions and information
  • Water-Year Summary reports summarize a year of hydrologic data in a printer-friendly format.
  • For water years 2014 onward, choose a water year and parameter and an on-demand Water-Year Summary report will be generated.
  • For water years 2006 through 2013, choose a water year and an Annual Water Data Report will be provided.
  • For water years 2005 and earlier, Annual Water Data Reports may be available in digital format.
  • Not all sites have reports available for every water year.
Available Parameters
00010 Temperature, water(Max.,Min.,Mean)  
00060 Discharge(Mean) [(2)]  
00060 Discharge(Mean)  
00095 Specific cond at 25C(Mean,Max.,Min.)  

Water year 2023: 2022-10-01 to 2023-09-30
 

Print this page
USGS Water-Year Summary 2023
01467087 FRANKFORD CREEK AT CASTOR AVENUE, PHILADELPHIA, PA
LOCATION - Lat 40°00'57", long 75°05'50" referenced to North American Datum of 1927, Philadelphia County, PA, Hydrologic Unit 02040202, on left bank at upstream side of Castor Avenue bridge, and 2.8 mi upstream from mouth in northeast Philadelphia.
DRAINAGE AREA - 30.4 mi².
REVISIONS HISTORY - WDR-US-2009: 2008.
SURFACE-WATER RECORDS
PERIOD OF RECORD - July 1982 to current year.
GAGE - Water-stage recorder, crest-stage gage, and concrete control. Datum of gage is 16.56 ft above National Geodetic Vertical Datum of 1929. Satellite telemetry at station.
COOPERATION - Station established and maintained by the U.S. Geological Survey. Funding for the operation of this station is provided by the City of Philadelphia, Water Department and the U.S. Geological Survey.
REMARKS - Records for water year 2014 are fair, except those for June 9-July 9 and July 15-July 29, due to orifice problems, those for discharges less than 50 ft³/s, those for discharges greater than 500 ft³/s, and those for estimated daily discharges, all of which are poor. Records for water year 2015 are fair, except those for discharges less than 50 ft³/s, those for discharges greater than 500 ft³/s, and those for estimated daily discharges, all of which are poor. Records for water year 2016 are fair, except those for discharges less than 50 ft³/s and greater than 500 ft³/s, which are poor.  Records for water year 2017 are fair, except those for discharges less than 10 ft³/s and greater than 500 ft³/s, which are poor. Records for water year 2018 are fair, except those for discharges less than 10 ft³/s and greater than 500 ft³/s, which are poor.
WATER-QUALITY RECORDS
PERIOD OF DAILY RECORD - October 2018 to current year.
COOPERATION - Station established and maintained by the U.S. Geological Survey. Funding for the operation of this station is provided by the City of Philadelphia, Water Department and the U.S. Geological Survey. 
INSTRUMENTATION - Water temperature and specific conductance probe interfaced with a data collection platform