Warning: Javascript must be enabled to use all the features on this page!


Page Loading - Please Wait...

* We've detected you're using a mobile device. Find our Next Generation Station Page here.
Click to hideNews Bulletins

Water-Year Summary for Site 14317450

Click to hide Water-Year Summary instructions and information
  • Water-Year Summary reports summarize a year of hydrologic data in a printer-friendly format.
  • For water years 2014 onward, choose a water year and parameter and an on-demand Water-Year Summary report will be generated.
  • For water years 2006 through 2013, choose a water year and an Annual Water Data Report will be provided.
  • For water years 2005 and earlier, Annual Water Data Reports may be available in digital format.
  • Not all sites have reports available for every water year.
Available Parameters
00010 Temperature, water(Max.,Min.,Mean)  
00095 Specific cond at 25C(Max.,Min.,Mean)  
00300 Dissolved oxygen(Max.,Min.,Mean)  
00400 pH(Max.,Min.,Med.)  
63680 Turbidity, Form Neph(Med.,Max.,Min.)  

Water year 2023: 2022-10-01 to 2023-09-30
 

Print this page
USGS Water-Year Summary 2023
14317450 NORTH UMPQUA RIVER NEAR IDLEYLD PARK, OR
LOCATION - Lat 43°19'29", long 122°59'55" referenced to North American Datum of 1927, in SW 1/4 NE 1/4 sec.12, T.26 S., R.3 W., Douglas County, OR, Hydrologic Unit 17100301, on right bank, 0.5 mi upstream from Rock Creek bridge, 2 mi east of Idleyld Park and at mile 36.3.
DRAINAGE AREA - 886 mi². at former site, 0.5 mi downstream.
WATER-QUALITY RECORDS
PERIOD OF DAILY RECORD -

SPECIFIC CONDUCTANCE:  January 1998 to current year.

pH:  January 1998 to current year.

WATER TEMPERATURE:  January 1998 to current year.

DISSOLVED OXYGEN:  January 1998 to current year.

TURBIDITY:  October 1999 to current year.

INSTRUMENTATION - Water-quality monitor. Any use of trade, product, or firm names in this publication is for descriptive purposes only and does not imply endorsement by the U.S. Government.
REMARKS - TURBIDITY:  Data collected using a YSI EXO2 sonde. Manufacturers stated accuracy is the greater of +/- 2 percent or 0.3 Formazin Nephelometric Units (FNU) except for 1,000-4,000 FNU, which is +/- 5 percent. Prior to Oct. 17, 2017, data collected using a YSI 6136 turbidity sensor. Manufacturers stated accuracy is the greater of +/- 5 percent or 2 FNU. FNU values below 10 are reported to nearest 0.1 FNU. Negative recorded values are reported as 0.0 FNU.
EXTREMES FOR PERIOD OF DAILY RECORD -

SPECIFIC CONDUCTANCE: Maximum, 79 microsiemens Sept. 20, 2021; minimum recorded, 26 microsiemens Nov. 21, 1998, Dec. 30, 2005, but may have been lower during period of missing record.

pH: Maximum, 9.8 units July 25, 2004; minimum recorded, 6.1 units Dec. 18, 1999, but may have been lower during period of missing record.

WATER TEMPERATURE: Maximum, 23.7°C June 28, 2021; minimum, 0.0°C Dec. 8-12, 2009, Dec. 8-11, 2013.

DISSOLVED OXYGEN: Maximum recorded, 16.1 mg/L Dec. 17, 2005, but may have been higher during period of missing record; minimum recorded, 6.4 mg/L Aug. 14, 2001.

TURBIDITY: Maximum recorded, 490 FNU Dec. 30, 2005, but may have been higher during period of missing record; minimum, <1 FNU on many days each year.