Data from 08/24/2000 to 01/14/2010 has been processed by the USGS with limited field water level measurements (18 measurements) made during the period to verify the recorded water levels. This record is considered good, except for the period July 15, 2003 to October 05, 2003 which is fair. Since the pressure transducer was installed on January 24, 2006, a instrument drift correction is frequently needed to adjust the prior recorded data to the current water level measurement. This correction is typically less than +/- 0.2 ft.
Data from 01/14/2010 to 08/18/2010 is good based on 3 water level measurements made during the period to verify the recorded water level data. The data is accurate to +/- 0.1 ft.
The record from 08/18/2010 to 08/15/2011 is good based on 4 water level measurements made during the period to verify the recorded water level data. The data is accurate to +/- 0.1 ft.
The record from 08/16/2011 to 08/29/2012 is fair based on 2 water level measurements made during the period. The data is accurate to +/- 0.1 ft. Instrument drift corrections were frequently needed to adjust the prior recorded data to the current water level measurement. This correction was ranged between -0.08 ft. to -0.23 ft.
The record from 08/29/2012 to 10/01 2013 is fair based on 4 water level measurements made during the period to verify the recorded data and is accurate to +/- 0.10 ft. Pressure transducer is starting to drift off and on in either direction and probably needs replaced.
The record from 10/02/2013 to 12/10/2014 is good based on 3 water level measurements made during the period to verify the recorded data and is accurate to +/- 0.10 ft.Pressure transducer is drifting from +0.18 ft. to -0.44 ft. Correction needed at each visit.
The record from 12/11/2014 to 04/04/2016 is good based on 3 water level measurements made during the period to verify the recorded data and is accurate to +/- .05 ft. Pressure transducer seemed to drift less in comparison to previous record periods. During this record period the transducer drifted from -0.02 ft. to +0.14 ft.
The record from 04/05/2016 to 09/20/2016 is good based on 2 water level measurements made during the period to verify the recorded data and is accurate to +/- .10 ft. Pressure transducer seems to consistently drift between measurements.
The record from 09/21/2016 to 04/04/2017 is good based on 1 water level measurement made during the period to verify the recorded data and is accurate to +/- .10 ft. Pressure transducer seems to consistently drift between measurements.
The record from 04/05/2017 to 03/28/2018 is good based on 1 water level measurement made during the period to verify the recorded data and is accurate to +/- .05 ft.
The record from 03/29/2018 to 09/24/2018 is good based on 1 water level measurement made during the period to verify the recorded data and is accurate to +/- 0.05 ft.
The record from 09/25/2018 to 01/09/2019 is good based on 1 water level measurement made during the period to verify the recorded data and is accurate to +/- 0.30 ft.
The record from 01/10/2019 to 06/24/2019 is good based on 1 water level measurement made during the period to verify the recorded data and is accurate to +/- 0.30 ft.
The record from 06/25/2019 to 01/08/2020 is good based on 1 water level measurement made during the period to verify the recorded data and is accurate to +/- 0.05 ft.
All further remarks can be found in RMS as of 01/09/2020.