Warning: Javascript must be enabled to use all the features on this page!


Page Loading - Please Wait...

Click to hideNews Bulletins

Water-Year Summary for Site 03083500

Click to hide state-specific text

[!] Over the next year, the USGS Pennsylvania Water Science Center will be updating the geodetic vertical elevation (gage datum) for many locations. Click HERE for additional information including a current list of streamgages with upcoming datum changes. This update in gage datum does not affect the location of the streamgage, nor the observed local gage height or discharge recorded at the streamgage.



Click to hide Water-Year Summary instructions and information
  • Water-Year Summary reports summarize a year of hydrologic data in a printer-friendly format.
  • For water years 2014 onward, choose a water year and parameter and an on-demand Water-Year Summary report will be generated.
  • For water years 2006 through 2013, choose a water year and an Annual Water Data Report will be provided.
  • For water years 2005 and earlier, Annual Water Data Reports may be available in digital format.
  • Not all sites have reports available for every water year.
Available Parameters
00010 Temperature, water(Max.,Min.,Mean)  
00060 Discharge(Mean)  
00095 Specific cond at 25C(Max.,Min.,Mean)  
00300 Dissolved oxygen(Max.,Min.,Mean)  
00400 pH(Max.,Min.,Med.)  

Water year 2023: 2022-10-01 to 2023-09-30
 

Print this page
USGS Water-Year Summary 2023
03083500 YOUGHIOGHENY RIVER AT SUTERSVILLE, PA
LOCATION - Lat 40°14'24.8", long 79°48'24.1" referenced to North American Datum of 1983, Allegheny County, PA, Hydrologic Unit 05020006, on left bank 500 ft upstream from highway bridge at Sutersville, 2.1 mi downstream from Sewickley Creek, at river mile 15.2.
DRAINAGE AREA - 1,715 mi².
REVISIONS HISTORY - WSP 743: Drainage area. WSP 1305: 1924, 1926 (M), 1931 (M). WSP 1435: 1935-36.
SURFACE-WATER RECORDS
PERIOD OF RECORD - October 1920 to current year. Monthly discharge for 1926, 1930, part of 1931, 1937, 1938, and part of 1939, published in WSP 1305.
GAGE - Water-stage recorder. Datum of gage is 732.76 ft above North American Vertical Datum of 1988.  Prior to June 1, 1939, non-recording gage at site 500 ft downstream at same datum.  Prior to January 4, 2024, the datum of gage was reported as 733.36 ft above National Geodetic Vertical Datum of 1929.  Satellite telemetry at station.
COOPERATION - Station established and maintained by the U.S. Geological Survey. Funding for the operation of this station is provided by the Pennsylvania Department of Environmental Protection, the U.S. Army Corps of Engineers, Pittsburgh District and the U.S. Geological Survey.
REMARKS - Flow regulated since January 1925 by Deep Creek Reservoir, 84 mi upstream, since December 1942 by Youghiogheny River Lake (station 03077000) 58 mi upstream, and by several smaller reservoirs. Records are good except for estimated daily discharge, which are poor.
WATER-QUALITY RECORDS
PERIOD OF RECORD - April 2002 to current year.
PERIOD OF DAILY RECORD - SPECIFIC CONDUCTANCE: June 2005 to September 2009 (seasonal); year-round data collection October 2009 to current year. pH: June 2005 to September 2009 (seasonal); year-round data collection October 2009 to current year. WATER TEMPERATURE: June 2005 to September 2009 (seasonal); year-round data collection October 2009 to current year. DISSOLVED OXYGEN: June 2005 to current year (seasonal).
COOPERATION - Water-quality samples were collected as part of the Pennsylvania Department of Environmental Protection Water-Quality Network (WQN) with cooperation from the Pennsylvania Department of Environmental Protection. Continuous record water-quality data supported by the U.S. Army Corps of Engineers, Pittsburgh District.
INSTRUMENTATION - Continuous water-quality monitor interfaced with a data collection platform with 15-minute recording interval. Data collected by the monitor may not be representative of the entire width of the river. Satellite telemetry at station.
REMARKS -

As of October 2013, results from discrete water quality samples collected at this site are available through the U.S. Geological Survey National Water Information System web interface on the "Water Quality for the Nation" webpage. Analyses for pH, water temperature, specific conductance, and dissolved oxygen were performed on site. Sample analyses were performed at the Pennsylvania Department of Environmental Protection laboratory in Harrisburg, PA. Occasionally, values for filtered parameters may exceed values for the corresponding unfiltered parameter. These results are within the limits of analytical precision and methods.

Historically, water temperatures below 0 degrees Celsius were not reported. Water temperature sensors now have the ability to accurately read water temperatures below 0 degrees Celsius. 

Data reported by the monitor may not be representative of the entire river width. Cross-sectional water quality data is available upon request.

Data collection for dissolved oxygen suspended in winter months. Other interruptions in the record were due to excessive fouling and malfunctions in the equipment.

For water year 2014: Water temperature, pH, and dissolved oxygen records are rated good. Specific conductance records are rated good, except for January 1 to 25 and April 23 to May 6, which are rated fair, and January 26 to March 28 and May 7 to 9, which are rated poor.

For water year 2015, records for water temperature, pH, and dissolved oxygen are rated good. Records for specific conductance are rated good, except for April 27 to May 1, which are fair, and for May 2 to May 5, which are poor.

For water year 2016, records for water temperature are rated good, except for May 3-16 and June 18 to September 27, which are fair, and May 17 to June 17, which are poor. Records for specific conductance are rated good, except for May 4 to June11 and June 20 to September 27, which are fair, and February 2 to May 3, which are poor. Records for pH are rated good, except for February 2 to September 27, which are fair. Records for dissolved oxygen are rated fair.

For water year 2017, records for water temperature are rated good. Records for specific conductance are rated good, except for December 20 to February 28, which are fair, and February 29 to April 25, which are poor. Records for pH are rated good, except for February 29 to August 7, which are fair. Records for dissolved oxygen are rated good, except for September 15-30, which are fair, and December 20 to August 7, which are poor.

For water year 2018, records for water temperature are rated good. Records for specific conductance are rated good, except for October 14-27, February 8-14, and May 10-September 30, which are fair, and for October 28-November 1, and February 15-March 12, which are poor. Records for pH are rated good, except for March 12, April 30-May 10, and September 25-30, which are fair, and for July 9-23, which are poor. Records for dissolved oxygen are rated fair.

For water year 2019, records for water temperature are rated good, except for June 24-September 30, which are fair. Records for specific conductance are rated fair, except for October 1 to June 24, which are poor. Records for pH are rated good, except for October 1 and June 24 to September 3, which are fair. Records for dissolved oxygen are rated fair, except for April 1 to June 24, which are poor. 

Beginning water year 2020, water quality records are no longer given qualitative ratings "excellent", "good", "fair", or "poor". 

EXTREMES FOR PERIOD OF RECORD - SPECIFIC CONDUCTANCE: Maximum, 804 microsiemens/cm, Feb 2, 2011; minimum, 95 microsiemens/cm, Mar 14, 2010. pH: Maximum, 9.0 standard units, Sep 26, 2011; minimum, 6.5 standard units, October 1, 13, 2012. WATER TEMPERATURE: Maximum, 31.4°C, Jul 7, 2012; minimum, -0.4°C, on many days during winter periods.