USGS Water-Year Summary 2024
02325543 FENHOLLOWAY RIVER NEAR HAMPTON SPRINGS, FL
LOCATION - Lat 30°00'40", long 83°46'40" referenced to North American Datum of 1927, in sec.25, T.5 S., R.5 E., Taylor County, FL, Hydrologic Unit 03110102,
DRAINAGE AREA - Indeterminate
SURFACE-WATER RECORDS
GAGE - Datum of gage is undetermined.
WATER-QUALITY RECORDS
PERIOD OF RECORD -
SPECIFIC CONDUCTANCE (TOP): March 2021 to October 2022.
SPECIFIC CONDUCTANCE (BOTTOM): March 2021 to current year.
WATER TEMPERATURE (TOP): March 2021 to October 2022.
WATER TEMPERATURE (BOTTOM): March 2021 to current year.
INSTRUMENTATION - Water-quality monitors consisting of temperature and specific conductivity.
EXTREMES FOR PERIOD OF RECORD - SPECIFIC CONDUCTANCE (Top): Maximum recorded, 42,700 us/cm Jan. 3, 2022; minimum recorded, 89 us/cm Mar. 15, 2022.
SPECIFIC CONDUCTANCE (Bottom): Maximum recorded 41,500 us/cm, Jan. 3, 2022; minimum recorded, 75 us/cm June 26, 2023.
WATER TEMPERATURE (Top): Maximum recorded, 29.1°C May 20, 2022; minimum recorded, 13.2°C Jan. 30, 2022.