Water-Year Summary for Site 07241000
WDR 2012: Drainage area.
Dissolved oxygen records for the period April 3, 2024, to April 24, 2024, were revised on September 17, 2024, a fouling error was discovered which changed the data.
10/1/2023 - 09/30/2024: records fair.
Quality of data for other periods can be obtained by contacting the Oklahoma-Texas Water Science Center.
Flow regulated by Canton Lake (station 07238500) and Lake Overholser (station 07240500). Diversions upstream from station into Lake Overholser and Lake Hefner Canal (station 07240000).
WATER TEMPERATURE: October 1988 to July 2023. Sonde was removed July 2023 - February 2024 due to ongoing construction activities. February 2024 - current year.
SPECIFIC CONDUCTANCE: October 1988 to July 2023. Sonde was removed July 2023 - February 2024 due to ongoing construction activities. February 2024 - current year.
pH: October 1988 to June 1991.
DISSOLVED OXYGEN: October 1988 to July 2023. Sonde was removed July 2023 - February 2024 due to ongoing construction activities. February 2024 - current year.
Accuracy rating of the record for the 2024 Water Year:
WATER TEMPERATURE: Good; The water quality monitor was temporarily removed from the site during WY2023 due to ongoing construction activities disrupting monitoring capabilities. No data was collected during this WY between 10/01/2023 - 02/21/2024. Data loss occurred throughout the year mostly due to equipment malfunctions. This sensor underwent NIST checks on a quarterly basis once being reinstalled, and one depth-integrated, EWI cross-section survey was completed within this water year.
SPECIFIC CONDUCTIVITY: Fair; The water quality monitor was temporarily removed from the site during WY2023 due to ongoing construction activities disrupting monitoring capabilities. No data was collected during this WY between 10/01/2023 - 02/21/2024. Fouling and calibration drift corrections were applied throughout the year. The magnitude of data loss, equipment malfunctions, and deletions reduced overall accuracy.
DISSOLVED OXYGEN: Poor; The water quality monitor was temporarily removed from the site during WY2023 due to ongoing construction activities disrupting monitoring capabilities. No data was collected during this WY between 10/01/2023 - 02/21/2024. Fouling and calibration drift corrections were applied throughout the year; large data corrections and portions of missing or deleted data reduced the overall accuracy. Efforts are being made by the QW team to increase the frequency of site visits to improve data quality and minimize fouling effects.
Quality of data for other periods can be obtained by contacting the Oklahoma-Texas Water Science Center.
WATER TEMPERATURE:
Maximum: 37.3°C on 09/27/2009
Minimum: -0.9°C on 03/04/2019*
SPECIFIC CONDUCTANCE:
Maximum: 1960 µS/cm on 06/18/2022
Minimum: 101 µS/cm on 02/05/2008
PH:
Maximum: 8.9 units on 10/27/1989*
Minimum: 6.2 units on 8/8/1989
DISSOLVED OXYGEN:
Maximum: 21.5 mg/l on 12/02/2009*
Minimum: 0.1 mg/L on 07/31/2012*
*Multiple occurrences of the same extreme following the date listed.