Warning: Javascript must be enabled to use all the features on this page!


Page Loading - Please Wait...

* We've detected you're using a mobile device. Find our Next Generation Station Page here.
Click to hideNews Bulletins

Water-Year Summary for Site 13019500

Click to hide Water-Year Summary instructions and information
  • Water-Year Summary reports summarize a year of hydrologic data in a printer-friendly format.
  • For water years 2014 onward, choose a water year and parameter and an on-demand Water-Year Summary report will be generated.
  • For water years 2006 through 2013, choose a water year and an Annual Water Data Report will be provided.
  • For water years 2005 and earlier, Annual Water Data Reports may be available in digital format.
  • Not all sites have reports available for every water year.
Available Parameters
00010 Temperature, water(Max.,Mean,Min.)  
00060 Discharge(Mean)  

Water year 2023: 2022-10-01 to 2023-09-30
 

Print this page
USGS Water-Year Summary 2023
13019500 HOBACK RIVER NEAR JACKSON, WY
LOCATION - Lat 43°18'19.0", long 110°40'48.7" referenced to North American Datum of 1983, in SW 1/4 NE 1/4 NE 1/4 sec.31, T.39 N., R.115 W., Teton County, WY, Hydrologic Unit 17040103, on downstream side of East Hoback River Road bridge, 1.0 mile downstream of Willow Creek, 3.5 miles upstream from mouth, and approximately 15 miles southeast of Jackson.
DRAINAGE AREA - 564 mi².  
SURFACE-WATER RECORDS
PERIOD OF RECORD - July 1917 to September 1918 (no winter records, published as "near Cheney"), October 1944 to September 1958, May 2022 to current year.  Monthly discharge only for October and November 1944, published in WSP 1317.
GAGE - Water-stage recorder. Elevation of gage is 6,060 ft above NAVD 1988, from handheld GPS.  July 10, 1917 to September 30, 1918 (no winter records), staff gage daily observation at site about 3.0 mi downstream from station at different datum.  October 8, 1944 to May 29, 1956, staff gage daily observation at site 0.85 mi upstream from station at different datum.  May 30, 1956 to September 30, 1958, staff gage at site 0.75 mi upstream from station at datum 0.92 ft lower than previous location.   U.S. Geological Survey data collection platform with satellite telemetry at station.
REMARKS - Small diversions above station for irrigation, amount of flow diverted unknown.
WATER-QUALITY RECORDS
PERIOD OF DAILY RECORD - WATER TEMPERATURE: May 2022 to current year. 
INSTRUMENTATION - Sutron Aquatemp thermistor 
REMARKS - Water-temperature records represent water temperature at sensor within 0.2°C. Maximum and minimum recorded values in the EXTREMES paragraphs may have occurred during days of partial record and may not appear in the daily values tables.
EXTREMES FOR PERIOD OF RECORD -