Water-Year Summary for Site 450543093105407
Water levels were recorded periodically from 04 October 2021 to 29 May 2024. Water levels were recorded every 5-minutes from 18 October 2021 at 16:20 CDT to 12 Feb. 2024 at 11:50 CST, except during the following periods:
18 Oct. 2021 at 16:20-17:55 CDT: due to WL equilibrating back to static after transducer deployment.
19 Nov. 2021 at 13:05-14:35 CST: due to replacing transducer during this period.
02 May 2022 at 12:55-22:05 CDT: due to deleting spike & equilibration data caused by QW sampling.
13 Jul. 2023 at 08:45-13:40 CDT: due to deleting spike & equilibration data caused by QW sampling.
10 Aug. 2022 at 07:40 CDT - 16 Nov. 2022 at 11:50 CST: due to sensor failure from animal chewing through sensor cable.
01 May 2023 at 13:05-17:00 CDT: due to deleting spike & equilibration data caused by QW sampling.
06 Jun. 2023 at 08:20-14:00 CDT: due to deleting spike & equilibration data caused by QW sampling.
27 Jun. 2023 at 10:35-15:20 CDT: due to deleting spike & equilibration data caused by QW sampling.
15 Aug. 2023 at 03:00 CDT - 16 Aug. 2023 at 12:55 CDT: due to dead station batteries & deleting spike during inspection.
12 Sept. 2023 at 10:20-13:50 CDT: due to deleting spike & equilibration data caused by QW sampling.
13 Sept. 2023 at 08:40-13:15 CDT: due to deleting spike & equilibration data caused by QW sampling.
14 Sept. 2023 at 08:00-12:20 CDT: due to deleting spike & equilibration data caused by QW sampling.
15 Sept. 2023 at 08:15-12:35 & 14:10-21:05 CDT: due to deleting spike & equilibration data caused by QW sampling.
15 Nov. 2023 at 10:10-11:20 CST: due to removing sensor from well during a sensor inspection.
15 Nov. 2023 at 11:25 CST - 12 Feb. 2024 at 11:50 CST: due to sensor failure from animal chewing through sensor cable.
Continuous water level, water temperature, specific conductance, and battery voltage were measured with a previously-used OTT CTD pressure transducer with a built-in specific conductance sensor. These data were recorded every 5-minutes from 19 November 2021 at 13:20 CST to 12 Feb. 2024 at 11:50 CST by the same OTT CTD pressure transducer, which had a data logger built into it. The data logger was housed inside a 4-inch diameter PVC pipe attached to the side of the well casing. The pressure transducer was powered by 3 AA alkaline batteries that were inside of the data logger communications rod. Data were downloaded manually and no telemetry at the gage.
The damaged OTT CTD pressure transducer was removed from the well on 12 Feb. 2024 at 11:50 CST.
Water quality samples have been collected periodically from 13 Oct. 2021 to 06 May 2024.
Water temperature (6.7 ft. BLS):
Water temperature was recorded every 5-minutes from 18 Oct. 2021 at 16:20 CDT to 19 Nov. 2021 at 13:05 CST, except during the following periods:
18 Oct. 2021 at 16:20-16:35 CDT: due to thermistor equilibrating to GW temperature after deployment.
Water temperature (8.0 ft. BLS):
Water temperature was recorded every 5-minutes from 19 Nov. 2021 at 13:20 CST to 12 Feb. 2024 at 11:50 CST, except during the following periods:
17 Feb. 2022 at 09:00-10:05 CST: due to removing sensor from well during a sensor inspection.
19 Oct. 2021 at 13:20-13:30 CDT: due to thermistor equilibrating to GW temperature after deployment.
17 Feb. 2022 at 09:10-10:25 CST: due to removing thermistor from well during a sensor inspection.
22 Feb. 2022 at 11:15-20:00 CST: due to deleting spike & equilibration data caused by QW sampling.
02 May 2022 at 13:00-15:00 CDT: due to deleting spike & equilibration data caused by QW sampling.
18 May 2022 at 08:40-12:20 CDT: due to removing thermistor from well during a sensor inspection.
13 July 2022 at 08:45-18:05 CDT: due to deleting spike & equilibration data caused by QW sampling.
10 Aug. 2022 at 07:50-08:55 CDT: due to removing thermistor from well during a sensor inspection.
10 Aug. 2022 at 09:00 CDT - 16 Nov. 2022 at 12:50 CDT: due to sensor failure from animal chewing through sensor cable.
10 Aug. 2022 at 12:55-15:50 CDT: due to thermistor equilibrating to GW temperature after deployment.
13 Feb. 2023 at 08:30-10:50 CST: due to removing thermistor from well during a sensor inspection.
06 Jun. 2023 at 08:20-17:50 CDT: due to deleting spike & equilibration data caused by QW sampling.
27 Jun. 2023 at 10:40-17:50 CDT: due to deleting spike & equilibration data caused by QW sampling.
15 Aug. 2023 at 03:00 CDT - 16 Aug. 2023 at 11:35 CDT: due to dead station batteries.
16 Aug. 2023 at 10:45-15:30 CDT: due to removing sensor from well during a sensor inspection.
15 Sept. 2023 at 14:10-19:45 CDT: due to deleting spike & equilibration data caused by QW sampling.
15 Nov. 2023 at 10:00-11:20 CST: due to removing sensor from well during a sensor inspection.
15 Nov. 2023 at 11:25 CST - 12 Feb. 2024 at 11:50 CST: due to sensor failure from animal chewing through sensor cable.
Specific Conductance, uS/cm, (8.0 ft. BLS):
Specific conductance was recorded every 5-minutes from 19 Nov. 2021 at 13:20 CST to 12 Feb. 2024 at 11:50 CST, except during the following periods:
17 Feb. 2022 at 09:00-10:05 CST: due to removing sensor from well during a sensor inspection.
22 Feb. 2022 at 11:55-19:05 CST: due to deleting spike & equilibration data caused by QW sampling.
02 May 2022 at 12:55-15:40 CDT: due to deleting spike & equilibration data caused by QW sampling.
16 May 2022 at 03:55-07:05 CDT: due to low battery voltage causing noisy and inaccurate data values.
16 May 2022 at 23:35-08:40 CDT: due to low battery voltage causing noisy and inaccurate data values.
17 May 2022 at 22:50 CDT to 18 May 2022 at 05:25 CDT: due to low battery voltage causing noisy and inaccurate values.
18 May 2022 at 08:00-08:35 CDT: due to low battery voltage causing noisy and inaccurate data values.
18 May 2022 at 08:50-10:00 CDT: due to removing sensor from well during a sensor inspection.
10 Aug. 2022 at 07:55 CDT - 16 Nov. 2022 at 11:50 CST: due to sensor failure from animal chewing through sensor cable.
16 Nov. 2022 at 13:25-16:00 CST: due to deleting equilibration data caused by sensor replacement.
11 Aug. 2023 at 21:05 CDT - 12 Aug. 2023 at 09:40 CDT: due to dead station batteries.
12 Aug. 2023 at 20:55 CDT - 16 Aug. 2023 at 10:40 CDT: due to dead station batteries.
12 Sept. 2023 at 10:25-19:20 CDT: due to deleting spike & equilibration data caused by QW sampling.
13 Sept. 2023 at 09:00-16:15 CDT: due to deleting spike & equilibration data caused by QW sampling.
15 Sept. 2023 at 08:15-01:25 CDT: due to deleting spike & equilibration data caused by QW sampling.
15 Nov. 2023 at 10:10-11:20 CST: due to removing sensor from well during a sensor inspection.
15 Nov. 2023 at 11:25 CST - 12 Feb. 2024 at 11:50 CST: due to sensor failure from animal chewing through sensor cable.