Water-Year Summary for Site USGS 07288068
The primary inside gage is a Sutron Auto Bubbler stage sensor and automatic purge system that is connected to an H-522+ Design Analysis Data Recorder with a 15-minute scan interval. The equipment is housed in a fiberglass half shelter, which is located on the downstream, right bank. The outside reference gage is a standard USGS wire weight gage attached to the downstream handrail of the bridge over the low water channel.
There is one ISCO 6712 sampler, which samples based on adjusted trigger stages.
Primary water quality gage is an Aqua Troll 600 multi-probe sensor which measures water temperature, DO, pH, Turbidity, and Dissolved Oxygen.
Datum of Gage is 126.79 ft above NAVD 88 (Reference Frame NAD_83 (2011) (EPOCH:2010.0000), GEOID 18).
Maximum instantaneous discharge = 734 cfs on March 10, 2016.
maximum instantaneous gage height = 27.32 feet on March 10, 2016.