Page Loading - Please Wait...
Water-Year Summary for Site 07160350
10/01/2021 - 09/30/2022: record fair. Quality of data for other periods can be obtained by contacting the Oklahoma-Texas Water Science Center. Low flows regulated by releases of effluent from the City of Enid water treatment plant, 250 feet upstream.
WATER TEMPERATURE: February 2012 to current year.
SPECIFIC CONDUCTANCE: February 2012 to current year.
Accuracy rating of the record for the 2022 Water Year:
WATER TEMPERATURE: Good; many deletions were applied. Data loss was not significant. The sensor was NIST checked on 2/8/2022 before installation, but a cross section survey was not completed within this water year.
SPECIFIC CONDUCTIVITY: Good; Several spike deletions were applied. Multiple fouling corrections were required while no calibration corrections were applied throughout the year. Data gaps occurred throughout the water year but were limited in scale. A cross section survey was not completed within this water year.
WATER TEMPERATURE
Maximum 37.79°C on 7/15/2017, 7/13/2022
Minimum -0.4°C on 1/17/2016-1/18/2016, & 1/19/2016
SPECIFIC CONDUCTANCE
Maximum 2320 µS/cm on 3/2/2015 & 3/3/2015
Minimum 96 µS/cm on 4/30/2012